| Base Station |
RS-IPS-2D(M) |
| Range |
up to 100 m diameter |
| Area of Operation |
300° around z-axis |
| Self Leveling Range * |
± 4° |
| Leveling Accuracy * |
± 10 arc seconds |
| Radio transmission |
433,92 MHz, ISM-Band. Class 1, power <=10 mw ERP, Duty-Cicle <10% |
| Power Source |
alkaline battery 908G (4R25),
rechargeable battery 6V 5000mAh or power supply unit 230V |
Battery Life
(rechargeable battery) |
approx. 8 hours |
| Laser Classification |
Class 1M, 658 nm visible Red |
| Water Resistance Level |
IPX5 |
Weight
(without battery) |
6,5 kg |
|
| Receiver |
RSD-IPS |
| Resolution |
cartesian coordinates |
|
x,y,z
|
0,1 mm
|
Accuracy
(Standarddeviation) |
cylinder coordinates
(referring to base station) |
| distance |
5 mm + 0,01 mm * R2 (R in meters) |
| angle |
10 arc seconds |
| Nivellement |
±1 mm + 0,1 mm/m, i dependent on the used sensor |
| Channels |
2-4 dependent on the used Model |
|
Measuring rate
|
2,5-10 Hz |
| Radio transmission |
433,92 MHz, ISM-Band. Class 1, power <=10 mw ERP, Duty-Cicle <10% |
| interface |
RS 232, other on request |
operating system used for the configuration-software |
MS Windows |
| Power supply |
5-8V DC, 400mA, other on request |
| Water Resistance Level |
IP65 |
| Weight
(without batteries) |
approx. 450 g |
|